What the Job Covers

Wood stoves wear in predictable places. Firebrick cracks, baffles warp, door rope flattens and lets air in, glass clouds or cracks, and catalytic combustors clog. We replace the worn parts with ones made for that stove, then check the connector pipe, the chimney it runs into, and the hearth pad or brick under it against the clearances on the stove's label. Parts are priced before we order them.

Cracked firebrick and warped baffles replaced
Door rope and glass seals renewed
Ceramic glass and catalytic combustors swapped
Connector pipe and chimney thimble looked at
Hearth pad and wall clearances measured

Seals, Bricks and Baffles Inside a Stove

Every bit of air should enter a wood stove where the controls let it in, so the fire can be turned down for a long, slow burn. When the door rope goes flat and hard, or the seal around the glass shrinks, air sneaks in around them, and the stove races through wood and will not settle. The bricks inside the stove are another item that wears; they keep direct flame off the steel, and once they split or fall out the steel behind them can warp. Above the fire sits a baffle, sometimes with steel tubes that feed extra air to burn off the smoke, and a sagged or cracked baffle lets smoke slip to the flue unburned, which means more tar in the chimney. Gaskets on the ash pan and any side loading door wear the same way.

We replace door and glass seals with rope of the correct diameter and the matching cement, cut and set new stove bricks to fit, and fit baffle parts made for the model. A cracked window gets new ceramic glass, never ordinary window glass. Hinges and latches that no longer pull the door tight are adjusted or replaced, since a perfect gasket does nothing if the latch cannot press the door onto it. Then we light a fire and confirm the stove turns down as it should. If the steel body itself has cracked through or a weld has failed, we tell you plainly whether a repair is sensible or whether the stove has reached the end of its life. If a part is no longer made for an older stove, we tell you before suggesting a substitute.

The Hearth and Chimney Behind the Stove

Our masonry trade matters as much as the stove parts here. A stove stands on a hearth pad and in front of a wall, and both are there to keep heat from reaching wood. Brick, stone or tile on a pad can crack and loosen as the floor flexes, and a cracked pad under a stove is a path for embers and heat. We reset loose units, replace cracked ones and check that the pad is large enough for the stove that now sits on it, which is not always the stove it was built for. Wall shields behind the stove are checked the same way, for spacing as well as for cracked tile or stone. A stove on a wood floor needs the right pad under it, and the right thickness of it, which depends on the stove.

Where a stove is set into an old masonry fireplace, the connector pipe often stops at the damper and the stove breathes into a flue sized for an open fire. The smoke slows and cools in that big flue and drops tar on the way up. Running a stainless liner the full height, sized for the stove, usually cures it. Stove repairs have no list price on this site; we look first, then put the stove parts, any masonry work and the liner, if one is needed, on one written quote with each part priced. Mention on the contact form what the stove is doing and how it is vented, and roughly how much you burn in a season, and we will arrange a visit before you need the heat.

How Chadwick Chimney Group Works

Matched Mortar

Mix and tint chosen against the joints already there

Water First

Crown, cap and flashing fixed before cosmetic work

Priced on Paper

Each line of the scope priced before a joint is cut

Photos Kept

Before and after pictures of the work in your report

Other Chadwick Services

Chimney Sweep

Creosote and soot scraped off the flue tile and the smoke shelf cleared, with the inside mortar joints read while the brushes are out.

Open the scope →

Chimney Inspection

A mason's read of the brick, mortar, crown, cap and flue, written down so you know which joints are holding and which are not.

Open the scope →

Chimney Repair

Open joints, broken crowns, cracked flue tile and loose brick fixed with mortar and units chosen to sit with the original work.

Open the scope →

Fireplace Inspection

Firebrick, refractory joints, damper, smoke chamber and hearth read by a mason, with distances to the wood trim measured and written down.

Open the scope →

Fireplace Repair

Firebrick relaid, refractory joints repointed, hearth units reset and smoke chamber parging renewed, so the firebox keeps its heat where it belongs.

Open the scope →

Chimney Level 2 Inspection

Every tile joint filmed to the top, with the attic and roof sections looked at, for sales, new appliances or after shaking.

Open the scope →

Chimney Cap Installation

A cap on the crown keeps rain off the flue tile and out of the mortar, with mesh that stops embers and animals.

Open the scope →

Chimney Flashing Repair

New step and counter flashing let into the brick's mortar joints, so the roof seal moves with the house instead of cracking off.

Open the scope →

Chimney Masonry Repair

Repointing, brick replacement and stone resetting with a mortar matched in strength, color and joint profile to the wall it joins.

Open the scope →

Chimney Rebuilds

A stack past repointing, taken down as far as the damage goes and relaid with steel, a new crown and new flue tile.

Open the scope →

Fireplace Cleaning

Ash out, soot off the firebrick and smoke stains lifted from the face brick or stone with cleaners that will not eat the mortar.

Open the scope →

Gas Fireplace Cleaning

Burner, pilot, log set and glass on a gas unit cleaned, and the firebox masonry or panels behind them looked over.

Open the scope →

Gas Fireplace Repair

Pilots, thermocouples, valves, igniters and remotes tested one at a time on gas fireplaces and inserts, with only the failed part changed.

Open the scope →

Fireplace Remodel

Old brick faces stripped, refaced or rebuilt, with stone, tile or new brick set over a firebox and hearth that are sound underneath.

Open the scope →

Fireplace Inserts

A gas or wood insert set into your existing brick firebox, with a stainless liner taken to the top and the surround brick repaired around the trim.

Open the scope →

Pellet Stove Repair

Auger jams, burned-out igniters, noisy fans and error codes traced part by part, with the vent pipe and hearth pad checked too.

Open the scope →

Gas Logs

Gas log sets fitted to a masonry firebox, burner, valve and damper set up so the flame burns clean against the brick.

Open the scope →

Chimney Seismic Retrofit

Brick stacks braced back to the house or rebuilt lighter above the roof, so the top is less likely to fall in a quake.

Open the scope →

Chimney Crown Repair

Crowns that have cracked or crumbled sealed, or broken off and recast in concrete with an overhang, so rain stops soaking the top courses.

Open the scope →

Dryer Vent Cleaning

Lint cleared from the dryer duct between the machine and the outside hood, and the hood flap freed so it opens and closes.

Open the scope →

Chimney Liner Installation

Stainless liners run through cracked or missing clay tile, wrapped where needed and capped, so flue gas never touches the brick.

Open the scope →

Chimney Leak Repair

Leaks traced by testing the flashing, crown, cap and face brick one at a time, then fixed where the water actually enters.

Open the scope →

Chimney Waterproofing

A silane or siloxane repellent on face brick that has already been repointed, so rain stays out while vapor still escapes.

Open the scope →

Chimney Damper Repair

Throat dampers freed or replaced, or a sealing top damper fitted on the flue tile when the old frame has rusted into the masonry.

Open the scope →

Chimney Chase Cover

A framed chimney's metal top, rebuilt in stainless to the chase's own size once the old one rusts and lets rain in.

Open the scope →