
Fireplace Inserts in Santa Clarita
Ask About This Job
Give the street and a line on what the chimney is doing. We reply to set a time for a mason to see it.
What the Job Covers
An insert only works as well as the masonry box and flue it sits in. We measure the opening front and rear, check the firebrick and smoke chamber, then set the insert and run a stainless liner up to a new top plate and cap. Where the old damper or smoke shelf is in the way, we cut back only what is needed. Setting a gas insert into a masonry box you already have runs $2,800 to $5,600.
Fitting an Insert to an Old Brick Fireplace
An insert is a closed steel or cast iron box set inside the old firebox, with a liner running from its collar to the top of the chimney and a trim panel covering the gap between the box and the brick face. The masonry has to be ready for it. The firebox floor must carry the weight, the opening must be big enough, and the flue has to be clear enough to pass the liner, which sometimes means cutting away part of the damper frame or the smoke shelf. Some older fireboxes have a raised lip or a hearth too short for an insert's front to rest on, and the quote includes building that out in matching brick or stone. We also confirm the opening sits far enough from wood trim for the model you choose, since each insert has its own spacing rules.
Before we quote, we take the firebox width and height in more than one spot, because old brick openings tend to be out of true, and check the flue so we know whether a liner will drop cleanly or catch on tiles that have shifted. Brick cracked around the opening, or a hearth that has dropped, is repaired first, so the insert is not set into masonry that is already moving. A crown with cracks gets attention too, because the liner's top plate seals against it, and a leaking crown will rust a new liner from the top down. In Santa Clarita many masonry fireplaces sit on an outside wall, and the brick there loses heat to the outdoors; an insert keeps the fire's heat in the room instead of soaking into that cold brick and sliding up the open flue. That is the main reason owners here switch.
Gas, Wood or Pellet, and the Prices
Gas is the most common choice in Santa Clarita: no wood to store, a flame at a switch, and usable on days when the air district bans wood burning. A sealed gas insert set into your existing fireplace costs $2,800 to $5,600 installed, the spread covering unit size and style and how much liner and gas line the job needs. Wood and pellet inserts are priced on a written quote once you choose a unit, because their models and liner sizes vary more. The installed figure for gas includes the liner from the insert to the top of the chimney, the top plate and cap, the trim panel, and connecting the gas at the firebox; a new gas run from the meter is listed separately when one is needed. Wood inserts still need a sound masonry chimney and a full liner, and they suit owners who burn often and have room to store wood.
If there is no fireplace where you want the heat, a direct vent gas unit can be framed into a wall with its own vent to the outside. That is a separate job, at $4,500 to $9,000, and it involves framing, finish work and a gas run rather than masonry. Before we leave an insert job, the unit is fired and watched through a full warm up, any gas joint is checked with a leak detector, and the trim panel is fitted tight to the brick so no gap shows. If the face itself needs work to suit the new insert, such as fresh tile or stone around the panel, we can price that remodel on the same quote. Describe the fireplace and what fuel you would like on the contact form, and we will arrange a visit to measure.
How Chadwick Chimney Group Works
Matched Mortar
Mix and tint chosen against the joints already there
Water First
Crown, cap and flashing fixed before cosmetic work
Priced on Paper
Each line of the scope priced before a joint is cut
Photos Kept
Before and after pictures of the work in your report
Fireplace Inserts by town
Each town page covers the local brick, mortar and weather, and how they shape this masonry job.
CA
Fireplace Inserts in Santa Clarita
A Newhall Land plan from the 1960s started Valencia, and tract building from the 1970s carried on in waves. When one of these houses has real masonry, we size the brick and tint the mortar so a patch disappears into the old work.
Read the town scopeCA
Fireplace Inserts in Burbank
Lots of fifties and sixties brick and block chimneys here got gas logs fitted later on. A gas log does nothing for an aging joint, so we cut out the soft mortar and repoint well before any brick can work loose.
Read the town scopeCA
Fireplace Inserts in Glendale
Rossmoyne, Brockmont Park, Cumberland Heights: these historic districts hold houses from the 1920s to 1940s whose brick was laid on site. We repoint that brick with a soft, lime-rich mortar, since a hard cement joint will crack old brick faces.
Read the town scopeCA
Fireplace Inserts in West Hollywood
Detached houses are only 9% of homes, so most fireplaces sit in courtyard buildings of the kind the Harper Avenue Historic District protects. On a brick stack serving several units, we match the face brick course for course when we rebuild.
Read the town scopeOther Chadwick Services
Chimney Sweep
Creosote and soot scraped off the flue tile and the smoke shelf cleared, with the inside mortar joints read while the brushes are out.
Open the scope →Chimney Inspection
A mason's read of the brick, mortar, crown, cap and flue, written down so you know which joints are holding and which are not.
Open the scope →Chimney Repair
Open joints, broken crowns, cracked flue tile and loose brick fixed with mortar and units chosen to sit with the original work.
Open the scope →Fireplace Inspection
Firebrick, refractory joints, damper, smoke chamber and hearth read by a mason, with distances to the wood trim measured and written down.
Open the scope →Fireplace Repair
Firebrick relaid, refractory joints repointed, hearth units reset and smoke chamber parging renewed, so the firebox keeps its heat where it belongs.
Open the scope →Chimney Level 2 Inspection
Every tile joint filmed to the top, with the attic and roof sections looked at, for sales, new appliances or after shaking.
Open the scope →Chimney Cap Installation
A cap on the crown keeps rain off the flue tile and out of the mortar, with mesh that stops embers and animals.
Open the scope →Chimney Flashing Repair
New step and counter flashing let into the brick's mortar joints, so the roof seal moves with the house instead of cracking off.
Open the scope →Chimney Masonry Repair
Repointing, brick replacement and stone resetting with a mortar matched in strength, color and joint profile to the wall it joins.
Open the scope →Chimney Rebuilds
A stack past repointing, taken down as far as the damage goes and relaid with steel, a new crown and new flue tile.
Open the scope →Fireplace Cleaning
Ash out, soot off the firebrick and smoke stains lifted from the face brick or stone with cleaners that will not eat the mortar.
Open the scope →Gas Fireplace Cleaning
Burner, pilot, log set and glass on a gas unit cleaned, and the firebox masonry or panels behind them looked over.
Open the scope →Gas Fireplace Repair
Pilots, thermocouples, valves, igniters and remotes tested one at a time on gas fireplaces and inserts, with only the failed part changed.
Open the scope →Fireplace Remodel
Old brick faces stripped, refaced or rebuilt, with stone, tile or new brick set over a firebox and hearth that are sound underneath.
Open the scope →Pellet Stove Repair
Auger jams, burned-out igniters, noisy fans and error codes traced part by part, with the vent pipe and hearth pad checked too.
Open the scope →Wood Stove Repair
Firebrick, baffles, gaskets, glass and combustors on wood stoves replaced, and the stovepipe and the hearth masonry under it checked.
Open the scope →Gas Logs
Gas log sets fitted to a masonry firebox, burner, valve and damper set up so the flame burns clean against the brick.
Open the scope →Chimney Seismic Retrofit
Brick stacks braced back to the house or rebuilt lighter above the roof, so the top is less likely to fall in a quake.
Open the scope →Chimney Crown Repair
Crowns that have cracked or crumbled sealed, or broken off and recast in concrete with an overhang, so rain stops soaking the top courses.
Open the scope →Dryer Vent Cleaning
Lint cleared from the dryer duct between the machine and the outside hood, and the hood flap freed so it opens and closes.
Open the scope →Chimney Liner Installation
Stainless liners run through cracked or missing clay tile, wrapped where needed and capped, so flue gas never touches the brick.
Open the scope →Chimney Leak Repair
Leaks traced by testing the flashing, crown, cap and face brick one at a time, then fixed where the water actually enters.
Open the scope →Chimney Waterproofing
A silane or siloxane repellent on face brick that has already been repointed, so rain stays out while vapor still escapes.
Open the scope →Chimney Damper Repair
Throat dampers freed or replaced, or a sealing top damper fitted on the flue tile when the old frame has rusted into the masonry.
Open the scope →Chimney Chase Cover
A framed chimney's metal top, rebuilt in stainless to the chase's own size once the old one rusts and lets rain in.
Open the scope →