Fireplace Inserts in Santa Clarita

Ask About This Job

What the Job Covers

An insert only works as well as the masonry box and flue it sits in. We measure the opening front and rear, check the firebrick and smoke chamber, then set the insert and run a stainless liner up to a new top plate and cap. Where the old damper or smoke shelf is in the way, we cut back only what is needed. Setting a gas insert into a masonry box you already have runs $2,800 to $5,600.

Opening measured front and rear before a model is named
Firebrick and smoke chamber checked first
Stainless liner run to a new top plate and cap
Damper or shelf cut back only as far as needed
Surround brick made good around the trim

Fitting an Insert to an Old Brick Fireplace

An insert is a closed steel or cast iron box set inside the old firebox, with a liner running from its collar to the top of the chimney and a trim panel covering the gap between the box and the brick face. The masonry has to be ready for it. The firebox floor must carry the weight, the opening must be big enough, and the flue has to be clear enough to pass the liner, which sometimes means cutting away part of the damper frame or the smoke shelf. Some older fireboxes have a raised lip or a hearth too short for an insert's front to rest on, and the quote includes building that out in matching brick or stone. We also confirm the opening sits far enough from wood trim for the model you choose, since each insert has its own spacing rules.

Before we quote, we take the firebox width and height in more than one spot, because old brick openings tend to be out of true, and check the flue so we know whether a liner will drop cleanly or catch on tiles that have shifted. Brick cracked around the opening, or a hearth that has dropped, is repaired first, so the insert is not set into masonry that is already moving. A crown with cracks gets attention too, because the liner's top plate seals against it, and a leaking crown will rust a new liner from the top down. In Santa Clarita many masonry fireplaces sit on an outside wall, and the brick there loses heat to the outdoors; an insert keeps the fire's heat in the room instead of soaking into that cold brick and sliding up the open flue. That is the main reason owners here switch.

Gas, Wood or Pellet, and the Prices

Gas is the most common choice in Santa Clarita: no wood to store, a flame at a switch, and usable on days when the air district bans wood burning. A sealed gas insert set into your existing fireplace costs $2,800 to $5,600 installed, the spread covering unit size and style and how much liner and gas line the job needs. Wood and pellet inserts are priced on a written quote once you choose a unit, because their models and liner sizes vary more. The installed figure for gas includes the liner from the insert to the top of the chimney, the top plate and cap, the trim panel, and connecting the gas at the firebox; a new gas run from the meter is listed separately when one is needed. Wood inserts still need a sound masonry chimney and a full liner, and they suit owners who burn often and have room to store wood.

If there is no fireplace where you want the heat, a direct vent gas unit can be framed into a wall with its own vent to the outside. That is a separate job, at $4,500 to $9,000, and it involves framing, finish work and a gas run rather than masonry. Before we leave an insert job, the unit is fired and watched through a full warm up, any gas joint is checked with a leak detector, and the trim panel is fitted tight to the brick so no gap shows. If the face itself needs work to suit the new insert, such as fresh tile or stone around the panel, we can price that remodel on the same quote. Describe the fireplace and what fuel you would like on the contact form, and we will arrange a visit to measure.

How Chadwick Chimney Group Works

Matched Mortar

Mix and tint chosen against the joints already there

Water First

Crown, cap and flashing fixed before cosmetic work

Priced on Paper

Each line of the scope priced before a joint is cut

Photos Kept

Before and after pictures of the work in your report

Other Chadwick Services

Chimney Sweep

Creosote and soot scraped off the flue tile and the smoke shelf cleared, with the inside mortar joints read while the brushes are out.

Open the scope →

Chimney Inspection

A mason's read of the brick, mortar, crown, cap and flue, written down so you know which joints are holding and which are not.

Open the scope →

Chimney Repair

Open joints, broken crowns, cracked flue tile and loose brick fixed with mortar and units chosen to sit with the original work.

Open the scope →

Fireplace Inspection

Firebrick, refractory joints, damper, smoke chamber and hearth read by a mason, with distances to the wood trim measured and written down.

Open the scope →

Fireplace Repair

Firebrick relaid, refractory joints repointed, hearth units reset and smoke chamber parging renewed, so the firebox keeps its heat where it belongs.

Open the scope →

Chimney Level 2 Inspection

Every tile joint filmed to the top, with the attic and roof sections looked at, for sales, new appliances or after shaking.

Open the scope →

Chimney Cap Installation

A cap on the crown keeps rain off the flue tile and out of the mortar, with mesh that stops embers and animals.

Open the scope →

Chimney Flashing Repair

New step and counter flashing let into the brick's mortar joints, so the roof seal moves with the house instead of cracking off.

Open the scope →

Chimney Masonry Repair

Repointing, brick replacement and stone resetting with a mortar matched in strength, color and joint profile to the wall it joins.

Open the scope →

Chimney Rebuilds

A stack past repointing, taken down as far as the damage goes and relaid with steel, a new crown and new flue tile.

Open the scope →

Fireplace Cleaning

Ash out, soot off the firebrick and smoke stains lifted from the face brick or stone with cleaners that will not eat the mortar.

Open the scope →

Gas Fireplace Cleaning

Burner, pilot, log set and glass on a gas unit cleaned, and the firebox masonry or panels behind them looked over.

Open the scope →

Gas Fireplace Repair

Pilots, thermocouples, valves, igniters and remotes tested one at a time on gas fireplaces and inserts, with only the failed part changed.

Open the scope →

Fireplace Remodel

Old brick faces stripped, refaced or rebuilt, with stone, tile or new brick set over a firebox and hearth that are sound underneath.

Open the scope →

Pellet Stove Repair

Auger jams, burned-out igniters, noisy fans and error codes traced part by part, with the vent pipe and hearth pad checked too.

Open the scope →

Wood Stove Repair

Firebrick, baffles, gaskets, glass and combustors on wood stoves replaced, and the stovepipe and the hearth masonry under it checked.

Open the scope →

Gas Logs

Gas log sets fitted to a masonry firebox, burner, valve and damper set up so the flame burns clean against the brick.

Open the scope →

Chimney Seismic Retrofit

Brick stacks braced back to the house or rebuilt lighter above the roof, so the top is less likely to fall in a quake.

Open the scope →

Chimney Crown Repair

Crowns that have cracked or crumbled sealed, or broken off and recast in concrete with an overhang, so rain stops soaking the top courses.

Open the scope →

Dryer Vent Cleaning

Lint cleared from the dryer duct between the machine and the outside hood, and the hood flap freed so it opens and closes.

Open the scope →

Chimney Liner Installation

Stainless liners run through cracked or missing clay tile, wrapped where needed and capped, so flue gas never touches the brick.

Open the scope →

Chimney Leak Repair

Leaks traced by testing the flashing, crown, cap and face brick one at a time, then fixed where the water actually enters.

Open the scope →

Chimney Waterproofing

A silane or siloxane repellent on face brick that has already been repointed, so rain stays out while vapor still escapes.

Open the scope →

Chimney Damper Repair

Throat dampers freed or replaced, or a sealing top damper fitted on the flue tile when the old frame has rusted into the masonry.

Open the scope →

Chimney Chase Cover

A framed chimney's metal top, rebuilt in stainless to the chase's own size once the old one rusts and lets rain in.

Open the scope →
Book a Mason